COMMERCIALTEMPERATURERANGE
16
IDTCV115-2
PROGRAMMABLEFLEXPCCLOCKFORP4PROCESSOR
Symbol
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
ppm
Long Accuracy(1)
See Tperiod Min. - Max. values
—
300
ppm
TPERIOD
Clock Period
14.318MHz output nominal
69.827
—
69.855
ns
VOH
Output HIGH Voltage(1)
IOH = -1mA
2.4
—
V
VOL
Output LOW Voltage(1)
IOL = 1mA
—
0.4
V
IOH
Output HIGH Current(1)
VOH at Min. = 1V, VOH at Max. = 3.135V
-29
—
-23
mA
IOL
Output LOW Current(1)
VOL at Min. = 1.95V, VOL at Max. = 0.4V
27
—
29
mA
tR1
Rise Time(1)
VOL = 0.4V, VOH = 2.4V
1
—
2
ns
tF1
FallTime(1)
VOL = 0.4V, VOH = 2.4V
1
—
2
ns
tSK1
Skew(1)
VT = 1.5V
—
500
ps
dT1
Duty Cycle(1)
VT = 1.5V
45
—
55
%
tJCYC-CYC
Jitter(1)
VT = 1.5V
—
1000
ps
ELECTRICAL CHARACTERISTICS - REF-14.318MHZ
Following Conditions Apply Unless Otherwise Specified:
Operating Condition: TA = 0°C to +70°C, Supply Voltage: VDD = 3.3V ± 5%; CL = 10 - 20pF
NOTE:
1.
This parameter is guaranteed by design, but not 100% production tested.